Completing the Installation
3-26 Installation
Completing the Installation of a DFE-Gold Module in an Existing
System
InanestablishedDFEGold modulesystem,
•aDFEGold moduleisalreadyestablishedasthemanagementmodule,
•thepasswordshavealreadybeensetforvarioususers,
•thesystemIPaddressisset,and
•othersystemparametershave beenset.
WhenyouinstallanewDFEGold moduleintoasystemwithanexistingconfigureduser
account,thecurrentsystemsettingsinthataccountarealreadyrecognizedbythenew
DFEGold moduleanditwilloperateaccordingly.
Ifyouneedtochangeanysettings,youcanconnectaterminaltothelocalconsoleportas
describedin“ConnectingtoCOMPortforLocalManagement”onpage 318
toaccess
systemmanagement,oruseaTelnetconnectiontoaccesstheDFEGold modulesystem
managementasdescribedinChapter3oftheEnterasysMatrixDFEGoldSeries
ConfigurationGuide.
Figure 3-12 Matrix Defogged Startup Screen Example (N7 Chassis)
login: admin
Password:
M A T R I X N7 GOLD
Command Line Interface
Enterasys Networks, Inc.
50 Minuteman Rd.
Andover, MA 01810-1008 U.S.A.
Phone: +1 978 684 1000
WWW: http://www.enterasys.com
(c) Copyright Enterasys Networks, Inc. 2003
Chassis Serial Number: xxxxxxxxxxxx
Chassis Firmware Revision: xx.xx.xx
Matrix N7(su)->