Enterasys SecureStack A2 A2H123-24 Guía de instalación

Busca en linea o descarga Guía de instalación para Los conmutadores de red Enterasys SecureStack A2 A2H123-24. Enterasys SecureStack A2 A2H123-24 Installation guide [en] [fr] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
7.5x9-inch cover with bleed on 4 sides
SecureStack A2
Fast Ethernet Switch
Hardware Installation Guide
A2H123-24
P/N 9034353-01
Vista de pagina 0
1 2 3 4 5 6 ... 63 64

Indice de contenidos

Pagina 1 - SecureStack A2

7.5x9-inch cover with bleed on 4 sidesSecureStack A2Fast Ethernet SwitchHardware Installation GuideA2H123-24P/N 9034353-01

Pagina 2

viii 3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateandfederalcourtsoftheCommonwealthofMas

Pagina 3 - Personal vorgenommen werden

ix8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramareofcriticalvaluetoEnterasys,and,a

Pagina 5 - HAZARDOUS SUBSTANCES

xiContentsAbout This GuideWho Should Use This Guide ...

Pagina 6 - (Circuit Breakers)

xiiConnecting to Console Port for Local Management ...3-15What Is Needed ...

Pagina 7

xiiiA-1 Console Port Pinout Assignments... A-3Tables3-1 Contents

Pagina 9

SecureStack A2 Installation Guide xvAbout This GuideThisguideprovidesanoverview,installationandtroubleshootinginstructions,andspecification

Pagina 10

How to Use This Guidexvi About This GuideHow to Use This GuideReadthroughthisguidecompletelytofamiliarizeyourselfwithitscontentsandgainan

Pagina 11

Conventions Used in This GuideSecureStack A2 Installation Guide xviiConventions Used in This Guide Thefollowingconventionsareusedinthisguide:N

Pagina 13 - Contents

Getting Helpxviii About This GuideGetting HelpForadditionalsupportrelatedtotheSecureStackA2orthisdocument,contactEnterasys Networksusing

Pagina 14 - Appendix A: Specifications

SecureStack A2 Installation Guide 1-11IntroductionThischapterintroducestheA2H123‐24stackableswitch.OverviewTheA2H123‐24isastackableFastE

Pagina 15

Overview1-2 Introduction• 1000BASE‐TRJ45connectorswhichcanbeusedinastackconfigurationorasstandardswitchportswhentheA2H123‐24isconf

Pagina 16

ConnectivitySecureStack A2 Installation Guide 1-3Stack ConnectionsTheswitcheshavefront‐panelRJ45connectorsforconnectionsinastackconfig ura

Pagina 17 - Who Should Use This Guide

Standards Compatibility1-4 IntroductionSwitch Configuration Using CLI CommandsTheCLIcommandsenableyoutoperformmorecompleteSecureStackA2conf

Pagina 18 - Related Documents

SecureStack A2 Installation Guide 2-12Network RequirementsBeforeinstallingthedevice,reviewtherequirementsandspecificationsinthischapter.T

Pagina 19

100BASE-TX Network2-2 Network Requirements100BASE-TX NetworkWhenconnectinga100BASE‐TXsegmenttooneofthefixedports(1 through24ontheA2H123

Pagina 20 - Getting Help

SecureStack A2 Installation Guide 3-13Hardware InstallationThischapterprovidesinstructionsonhowtoinstalltheA2H123‐24.Followtheorderofth

Pagina 21 - A2H123-24 Switch

Considerations Prior to Installation3-2 Hardware InstallationConsiderations Prior to InstallationWheninstallingtheswitch,notethefollowing:•Befor

Pagina 22 - A2H123-24

Installing the Switch on a Flat SurfaceSecureStack A2 Installation Guide 3-3Installing the Switch on a Flat SurfaceWheninstallingtheswitchonafl

Pagina 23 - Management

iNoticeEnterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthisdocumentanditswebsitewitho

Pagina 24 - LANVIEW Diagnostic LEDs

Installing the Switch on a Flat Surface3-4 Hardware InstallationFigure 3-1 Chassis Bottom, Rubber Feet Placement1 Bottom of chassis as seen when chas

Pagina 25 - 10BASE-T Network

Installing the Switch on a Flat SurfaceSecureStack A2 Installation Guide 3-5Guidelines for Flat Surface InstallationLocatetheswitchwithin152cm(

Pagina 26 - 1000BASE-T Network

Rack Mounting the Switch3-6 Hardware InstallationRack Mounting the Switch Toinstalltheswitchina19‐inchrack,youneed:•Tworackmountbracketsa

Pagina 27 - Hardware Installation

Connecting Stacking CablesSecureStack A2 Installation Guide 3-7Figure 3-3 Attaching the Rackmount Brackets2. Withthemountingbracketsattached,po

Pagina 28 - Unpacking the Switch

Connecting Stacking Cables3-8 Hardware InstallationFigure 3‐5showsanexampleofafour‐highstackconnectedinaclosedloopconfiguration.AllSTAC

Pagina 29 - Installing the Rubber Feet

Configuring Switches in a StackSecureStack A2 Installation Guide 3-9Configuring Switches in a StackTheinformationinthefollowingsectionsisimpor

Pagina 30 - 3-4 Hardware Installation

Configuring Switches in a Stack3-10 Hardware Installation3. Themanagementelectionprocessusesthefollowingprecedencetoassignamanagementswitc

Pagina 31 - referto

Configuring Switches in a StackSecureStack A2 Installation Guide 3-113. Oncethedesiredmasterunithasbeenselected,resetthesystemusingthere

Pagina 32 - Rack Mounting the Switch

Connecting AC and RPS-SYS Power3-12 Hardware InstallationConnecting AC and RPS-SYS PowerAC PowerToconnectaswitchtotheACpowersource,refertoF

Pagina 33 - Connecting Stacking Cables

Connecting AC and RPS-SYS PowerSecureStack A2 Installation Guide 3-13Figure 3-6 Switch Rear View 3. ObservethepowerCPULED(notshown),locatedo

Pagina 34 - 3 STACK DOWN connector

ii REGULATORY COMPLIANCE INFORMATIONFEDERAL COMMUNICATIONS COMMISSION (FCC) NOTICEThisdevicecomplieswithPart15oftheFCCrules.Operationissub

Pagina 35

Connecting AC and RPS-SYS Power3-14 Hardware InstallationC2RPS-SYS Redundant Power SystemIfyouareinstallinganoptionalredundantpowersystem(C2R

Pagina 36 - Important

Connecting to Console Port for Local ManagementSecureStack A2 Installation Guide 3-15Stack Initialization OverviewWhenyouinstallandconnectallth

Pagina 37

Connecting to Console Port for Local Management3-16 Hardware InstallationUsingaDTEmodemDB9female‐to‐DB25femalecable,youcanconnectproductse

Pagina 38 - AC Power

Connecting to Console Port for Local ManagementSecureStack A2 Installation Guide 3-17Whentheseparametersareset,theStartupscreenwilldisplay.

Pagina 39

Connecting to Console Port for Local Management3-18 Hardware InstallationWhentheseparametersareset,theStartupscreenwilldisplay.Proceedto“C

Pagina 40 - 3-14 Hardware Installation

Connecting to the NetworkSecureStack A2 Installation Guide 3-19Whentheseparametersareset,theStartupscreenwilldisplay.Iftheswitchesarein

Pagina 41 - What Is Needed

Connecting to the Network3-20 Hardware InstallationToconnecttwistedpairsegmentstotheswitch,refertoFigure 3‐12andproceedasfollows:1. Ensu

Pagina 42 - 3-16 Hardware Installation

Connecting to the NetworkSecureStack A2 Installation Guide 3-21d. EnsurethatthetwistedpairconnectionmeetsthedBlossandcablespecifications

Pagina 43

Connecting to the Network3-22 Hardware InstallationFigure 3-15 Eight-Wire Crossover Cable RJ45 Pinouts for 1000BASE-TXFigure 3-16 Eight-Wire Straigh

Pagina 44 - Connecting to a Modem

Connecting to the NetworkSecureStack A2 Installation Guide 3-23Connecting Fiber-Optic Cables to LC PortsThissectiondescribeshowtoconnecta100BA

Pagina 45 - Connecting to the Network

iiiELECTROMAGNETIC COMPATIBILITY (EMC)Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,EN61000‐3‐2,

Pagina 46 - 3-20 Hardware Installation

Connecting to the Network3-24 Hardware InstallationFigure 3-17 Cable Connection to LC Fiber-Optic Connectors3. Plug theotherendofthecableinto

Pagina 47

Completing the InstallationSecureStack A2 Installation Guide 3-255. Repeatsteps 1throu gh4,above,untilallconnectionshavebeenmade.Completin

Pagina 48 - 3-22 Hardware Installation

Completing the Installation3-26 Hardware Installation

Pagina 49

SecureStack A2 Installation Guide 4-14TroubleshootingThischapterprovidesinformationconcerningthefollowing:Thisdevicecontainsabatterythati

Pagina 50 - 3-24 Hardware Installation

Using LANVIEW4-2 TroubleshootingUsing LANVIEWTheseswitchessupporttheEnterasys Networksbuilt‐inLANVIEWLEDvisualdiagnosticandstatusmonitorin

Pagina 51 - Completing the Installation

Using LANVIEWSecureStack A2 Installation Guide 4-3Table 4-1 LANVIEW LEDsLED Color State Recommended ActionCPU Off Power disconnected. If the LED rema

Pagina 52 - 3-26 Hardware Installation

Using LANVIEW4-4 Troubleshooting26/Stack DownOff No valid connection to switch stackup connector.1. Make sure the switch connected to the stackup conn

Pagina 53 - Troubleshooting

Using LANVIEWSecureStack A2 Installation Guide 4-5RPS Off The RPS LED remains off regardless if the RPS is attached or not. The LED being in its off

Pagina 54 - Using LANVIEW

Troubleshooting Checklist4-6 TroubleshootingTroubleshooting ChecklistIfthedeviceisnotworkingproperly,refertoTable 4‐2forachecklistofprob

Pagina 55 - Table 4-1 LANVIEW LEDs

Troubleshooting ChecklistSecureStack A2 Installation Guide 4-7Cannot contact the SecureStack A2 through in-band management.IP address not assigned. R

Pagina 56 - 4-4 Troubleshooting

iv ѻѻક䇈ᯢк䰘ӊSupplement to Product Instructions ᳝↦᳝ᆇ⠽䋼៪ܗ㋴(Hazardous Substance) 䚼ӊৡ⿄(Parts) 䪙3E∲+J䬝&G݁Ӌ䫀&U໮⒈㘨㣃3%%໮⒈Ѡ㣃䝮3%&apo

Pagina 57

Using the Reset Switch4-8 TroubleshootingUsing the Reset SwitchIfyouforgettheSecureStackA2loginpassword,usetheResetswitchasdescribedint

Pagina 58 - Troubleshooting Checklist

SecureStack A2 Installation Guide A-1ASpecificationsThisappendixprovidesinformationaboutthefollowing:Enterasys Networksreservestherighttoc

Pagina 59

Switch SpecificationsA-2 SpecificationsAC Input SpecificationsInput Voltage 100 – 240 VACInput Current 1 A MaxFrequency 50 – 60 HzProcessors/MemoryPro

Pagina 60 - Using the Reset Switch

SecureStack A2 Installation Guide A-3Fiber-Optic SpecificationsTwo10 0BASE‐FXfiberports(Multimode)withLCconnectorsarelocatedonthe frontp

Pagina 61 - Switch Specifications

Torque ValuesA-4 SpecificationsTorque ValuesThefollowingtabledescribestherecommendedtorquevaluestousewheninstallingtheSecureStackswitch

Pagina 62 - Item Specification

vVCCI NOTICEThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformationTechnologyEquipment(VCC

Pagina 63 - Fiber-Optic Specifications

vi DECLARATION OF CONFORMITYApplicationofCouncilDirective(s): 89/336/EEC73/23/EECManufacturer’sName: Enterasys Networks, Inc.Manufacturer’sAddres

Pagina 64 - Regulatory Compliance

viiENTERASYS NETWORKS, INC. FIRMWARE LICENSE AGREEMENTBEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,CAREFULLY READ THIS LICENSE AGREEMENT.Thisdocu

Comentarios a estos manuales

Sin comentarios