Enterasys SecureStack A2 A2H124-48P Especificaciones Pagina 118

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 634
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 117
Startup and General Configuration Summary
Configuring Power over Ethernet (PoE)
2-86 SecureStack A2 Configuration Guide
2.1.13.5 set port inlinepower
Use this command to configure PoE parameters on one or more ports.
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high |
low}] [type type]}
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to enable PoE on port fe.3.1 with critical priority:
port-string Specifies the port(s) on which to configure PoE.
admin off | auto Sets the PoE administrative state to off (disabled) or auto
(on).
priority critical |
high | low
Sets the port(s) priority for the PoE allocation algorithm to
critical (highest), high or low.
type type Specifies a string describing the type of switch connected
to a port.
A2(rw)->set port inlinepower fe.3.1 admin auto priority critical
Vista de pagina 117
1 2 ... 113 114 115 116 117 118 119 120 121 122 123 ... 633 634

Comentarios a estos manuales