Spanning Tree Configuration Command Set
Reviewing and Setting Spanning Tree Bridge Parameters
SecureStack A2 Configuration Guide 5-47
5.2.1.40 set spantree spanguardtimeout
Use this command to set the amount of time (in seconds) an edge port will remain locked by the
span guard function.
set spantree spanguardtimeout timeout
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to set the span guard timeout to 600 seconds:
timeout Specifies a timeout value in seconds. Valid values are 0 to
65535.
A value of 0 will keep the port locked until manually
unlocked. The default value is 300 seconds.
A2(rw)->set spantree spanguardtimeout 600