Enterasys Matrix 7GR4202-30 Guía de instalación Pagina 44

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 92
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 43
Installing the Device
3-16 Hardware Installation
3.7 INSTALLING THE DEVICE
For a tabletop or shelf installation, locate the device within seven feet of its power source and on an
unrestricted free surface area as shown in Figure 3-7. Proceed to Section 3.7.4 for power
connection instructions.
Figure 3-7 Clearance Required for Tabletop or Shelf Installation
3.7.1 Rackmount Installation
To install the device in a 19-inch rack, you need following items shipped with the device:
A strain-relief bracket and mounting screws (cable management kit)
Two rackmount brackets and mounting screws (rackmount kit)
Also needed are four user-supplied screws to attach the device to a standard 19-inch rack.
CAUTION: To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in) at the left, right, and rear of the device.
C
A = 15 cm (6 in)
B = 57 cm (22.5 in)
C = 53 cm (21 in)
D = 213 cm (7 ft)
A
D
-
B
2
1
4
6
8
10 12 14 16
3
5
7
9 11 13 15
18
17
20
22
24
26 28 30 32
19
21
23
25 27 29 31
34
33
36
38
40
42 44 46 48
35
37
39
41 43 45 47
Reset
Console
PWR
CPU
1H582-51
Vista de pagina 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 91 92

Comentarios a estos manuales

Sin comentarios