Connecting to COM Port for Local Management
4-16 NAC Controller PEP Installation
Figure 4-13 Connecting a VT Series Terminal
Connecting to a Modem
ToconnectamodemtoanEnterasys NetworkschassisCOMport(Figure 414),useaUTP
straightthroughcablewithRJ45connectorsandanRJ45toDB25maleadapter,andproceedas
follows:
1. ConnecttheRJ45connectoratoneendoftheUTPstraightthroughcable
totheCOMportof
themodule.
2. PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintothe
RJ45toDB25modemadapter.
3. ConnecttheRJ45toDB25adaptertothecommunicationsportonthemodem.
4. Turnonthemodem.
5. WithaPCconnectedtoaremotemodem,
youcanconfiguretheswitchremotely.To
accomplishthis,youmustconfigureyourPCVTemulation packagewiththefollowing
parameters:
6. Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.Referto
theEnterasysMatrixDFEDiamond/PlatinumSeriesConfigurationGuideforfurtherinformation.
1 UTP straight-throughcable with RJ45 connectors 3 RJ45-to-DB25 VT adapter
2 RJ45 COM port 4 VT series terminal
Parameter Setting
Mode 7 Bit Control
Transmit Transmit=9600
Bits Parity 8 Bits, No Parity
Stop Bit 1 Stop Bit