Vista de pagina 310
VLAN Configuration Command Set
Assigning Port VLAN IDs (PVIDs) and Ingress Filtering
SecureStack B2 Configuration Guide 6-15
6.3.3.3 clear port vlan
Use this command to reset a port’s 802.1Q port VLAN ID (PVID) to the host VLAN ID 1.
clear port vlan port-string
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to reset the Fast Ethernet ports 3 and 11 in unit1 to a VLAN ID of 1 (Host
VLAN):
port-string Specifies the port(s) to be reset to the host VLAN ID 1. For
a detailed description of possible port-string values, refer to
Section 3.1.1.
B2(rw)->clear port vlan fe.1.3,fe.1.11