Security Configuration Command Set
Configuring VLAN Authorization (RFC 3580)
SecureStack B2 Configuration Guide 11-29
11.3.3 Configuring VLAN Authorization (RFC 3580)
Purpose
Please see section 3-31 of RFC 3580 for details on configuring a RADIUS server to return the
desired tunnel attributes. From RFC 3580, “... it may be desirable to allow a port to be placed into
a particular Virtual LAN (VLAN), defined in [IEEE8021Q], based on the result of the
authentication ..”
The RADIUS server typically indicates the desired VLAN by including tunnel attributes within the
Access-Accept. However, the IEEE 802.1X Authenticator may also provide a hint as to the VLAN
to be assigned to the Supplicant by including Tunnel attributes within the Access-Request.
For use in VLAN assignment, the following tunnel attributes are used:
Tunnel-Type=VLAN (13)
Tunnel-Medium-Type=802
Tunnel-Private-Group-ID=VLANID
Commands
The commands used to configure RADIUS tunnel attributes are listed below and described in the
associated sections as shown.
set vlanauthorization (Section 11.3.3.1)
set vlanauthorization egress (Section 11.3.3.2)
clear vlanauthorization (Section 11.3.3.3)
show vlanauthorization (Section 11.3.3.4)