Logging And Network Management Command Set
Configuring System Logging
SecureStack B2 Configuration Guide 10-9
10.2.1.6 clear logging default
Use this command to reset logging default values.
clear logging default{[facility] [severity] [port]}
Syntax Description
Command Defaults
At least one optional parameter must be entered.
All three optional keywords must be entered to reset all logging values to
defaults.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to reset the Syslog default severity level to 6:
facility (Optional) Resets the default facility name to local4.
severity (Optional) Resets the default logging severity level to 6
(notifications of significant conditions).
port (Optional) Resets the default UDP port the client uses to
send to the server to 514.
B2(rw)->clear logging default severity