Startup and General Configuration Summary
Setting Basic Device Properties
2-64 SecureStack B2 Configuration Guide
2.1.12.21 set logout
Use this command to set the time (in minutes) an idle console or Telnet CLI session will remain
connected before timing out.
set logout timeout
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to set the system timeout to 10 minutes:
timeout Sets the number of minutes the system will remain idle
before timing out.
B2(rw)->set logout 10