Troubleshooting Checklist
Troubleshooting 4-7
User parameters
(IP address,
device and
module name,
etc.) were lost
when the module
power was
cycled, the front
panel RESET
button was
pressed.
Position of Mode switch
(7), Persistent Data Reset,
was changed sometime
before either cycling
power or pressing the
RESET button, causing the
user-entered parameters to
reset to factory default
settings.
Clear Persistent Data that
was set through Local
Management.
The module was moved
either from slot-to-slot or
from chassis-to-chassis.
Reenter the lost parameters as necessary.
Refer to the Enterasys Matrix DFE-Platinum
Series Configuration Guide for the
instructions to configure the device.
If the problem continues, contact Enterasys
Networks for technical support.
Table 4-2 Troubleshooting Checklist (Continued)
Problem Possible Cause Recommended Action