set inlinepower trap
SecureStack B2 Configuration Guide 5-3
Usage
ThethresholdisexpressedasapercentageoftheavailablePoEpower.Whenthisthresholdis
reached,atrapwillbesentiftrapsareenabledwiththesetinlinepowertrapcommand.
Example
Thisexampleshowshowtosetthepowerthresholdto90onmodule/unit1:
B2(su)->set inlinepower threshold 90 1
set inlinepower trap
UsethiscommandtoenableordisablethesendingofanSNMPtrapmessageforaunitormodule
wheneverthestatusofitsportschanges,orwhenevertheunit’spowerusagethresholdiscrossed.
Syntax
set inlinepower trap {disable | enable} module-number
Parameters
Defaults
Sendingoftrapsisdisabledbydefault.
Mode
Switchcommand,readwrite.
Usage
Themodule’sorunit’spowerusagethresholdmustbesetusingthesetinlinepowerthreshold
commandasdescribedonpage52.
Example
Thisexampleshowshowtoenableinlinepowertrapmessagingonmodule1:
B2(su)->set inlinepower trap enable 1
set inlinepower detectionmode
UsethiscommandtospecifythemethodtheswitchwillusetodetectPDs(powereddevices)
connectedtoitsports.
Syntax
set inlinepower detectionmode {auto | ieee)
disable|enable Disablesorenablesinlinepowertrapmessaging.
modulenumber Specifiesthemoduleorunitonwhichtodisableorenabletrapmessaging.