Enterasys Enterasys SecureStack B2 B2G124-24 Especificaciones Pagina 573

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 600
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 572
show vlanauthorization
SecureStack B2 Configuration Guide 19-49
Mode
Switchcommand,readwrite.
Example
ThisexampleshowhowtoclearVLANauthorizationforallportsonslots3,4,and5:
B2(rw)->clear vlanauthorization ge.3-5.*
show vlanauthorization
DisplaystheVLANauthenticationstatusandconfigurationinformationforthespecifiedports.
Syntax
show vlanauthorization [port-string]
Parameters
Defaults
Ifnoportstringisentered,thestatusforallportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThiscommandshowshowtodisplayVLANauthorizationstatusfor ge.1.1:
B2(su)>showvlanauthorizationge.1.1
VlanAuthorization:‐enabled
port status administrative operational authenticated vlan id
egress egress mac address
------- -------- -------------- ----------- ----------------- -------
ge.1.1 enabled untagged
Table 195providesanexplanation ofcommandoutput.Fordetailsonenablingandassigning
protocolandegressattributes,refertosetvlanauthorizationonpage 1947andset
vlanauthorizationegressonpage 1948.
portstring (Optional)DisplaysVLANauthenticationstatusforthespecifiedports.If
noportstringisentered,then
theglobalstatusofthesettingisdisplayed.
Foradetaileddescriptionofpossibleportstringvalues,refertoPort
StringSyntaxUsedintheCLIonpage 72.
Table 19-5 show vlanauthorization Output Details
Output Field What It Displays...
port Port identification
status Port status as assigned by set vlanauthorization command
administrative
egress
Port status as assigned by the set vlanauthorization egress command
operational egress Port operational status of vlanauthorization egress.
Vista de pagina 572
1 2 ... 568 569 570 571 572 573 574 575 576 577 578 ... 599 600