Vista de pagina 140
set lldp trap-interval
SecureStack B2 Configuration Guide 6-23
set lldp trap-interval
UsethiscommandtosettheminimumintervalbetweenLLDPnotificationssentbythisdevice.
LLDPnotificationsaresentwhenaremotesystemchangehasbeendetected.
Syntax
set lldp trap-interval frequency
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexamplesetstheminimumintervalbetweenLLDPtrapsto10seconds.
B2(rw)->set lldp trap-interval 10
set lldp med-fast-repeat
NetworkconnectivitydevicestransmitonlyLLDPTLVsinLLDPDUsuntiltheydetectthatan
LLDPMEDendpointdevicehasconnectedtoaport.Atthatpoint,thenetworkconnectivity
devicestartssendingLLDPMEDTLVsatafaststartrateonthatport.Usethiscommandtosetthe
numberof
successiveLLDPDUs(withLLDPMEDTLVs)tobesentforonecompletefaststart
interval.
Syntax
set lldp med-fast-repeat count
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
frequency SpecifiestheminimumtimebetweenLLDPtraptransmissions,in
seconds.Thevaluecanrangefrom5to3600seconds.Thedefault
valueis5seconds.
count SpecifiesthenumberoffaststartLLDPDUstobesentwhenan
LLDPMEDendpointdeviceisdetected.Valuecanrangefrom1to
10.Defaultis3.