Enterasys Enterasys SecureStack B2 B2G124-24 Especificaciones Pagina 65

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 600
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 64
show system
SecureStack B2 Configuration Guide 3-13
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetthemethodusedtoacquireanetworkIPaddresstoDHCP.
B2(su)->set ip protocol dhcp
show system
Usethiscommandtodisplaysysteminformation,includingcontactinformation,powerandfan
traystatusanduptime.
Syntax
show system
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaysysteminformation:
B2(su)->show system
System contact:
System location:
System name:
Switch 1
--------
PS1-Status PS2-Status
---------- ----------
Ok Not Installed and/or Not Operating
Fan1-Status Fan2-Status
----------- -----------
Ok Ok
Temp-Alarm
-----------
off
Thermal Threshold: 58%
Temp alarm max threshold: 100%
Temp alarm trap: disabled
Temp alarm syslog: disabled
Uptime d,h:m:s Logout
-------------- -------
0,20:36:49 0 min
Vista de pagina 64
1 2 ... 60 61 62 63 64 65 66 67 68 69 70 ... 599 600

Comentarios a estos manuales

Sin comentarios