Vista de pagina 362
clear cos settings
SecureStack B2 Configuration Guide 12-23
•IRLReference
TheCoSIRLreferencefieldisoptional,asratelimitsarenotrequired.TheIRLreferencedoes
notassignaninboundratelimitbutpointstotheCoSIRLReferenceMappingTable.This
referencemaybethoughtofasthevirtualratelimiterthatwillassignthephysicalrate
limiter
definedbytheIRLReferenceMappingTable.
Example
ThisexampleshowshowtocreateCoSentry8withapriorityvalueof3:
B2(rw)->set cos settings 8 priority 3
clear cos settings
UsethiscommandtoclearClassofServiceentrysettings.
Syntax
clear cos settings cos-list {[all] | [priority] [tos-value] [irl-reference]}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoclearthepriorityforCoSentry8:
B2(rw)->clear cos settings 8 priority
show cos settings
UsethiscommandtodisplayClassofServiceparameters.
Syntax
show cos settings [cos-list]
Parameters
coslist SpecifiesaClassofServiceentrytoclear.
all Clearsallsettingsassociatedwiththisentry.
priority Clearsthepriorityvalueassociatedwiththisentry.
tosvalue ClearstheTypeofServicevalueassociatedwiththisentry.
irlreference CleartheIRLreferenceassociatedwiththisentry.
coslist (Optional)SpecifiesaClassofServiceentrytodisplay.