set spantree lpwindow
9-48 Spanning Tree Configuration
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheLoopProtecteventthresholdtothedefaultof3:
B2(rw)->clear spantree lpthreshold
set spantree lpwindow
UsethiscommandtosettheLoopProtecteventwindowvalueinseconds.
Syntax
set spantree lpwindow value
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
TheLoopProtectWindowisatimer value,inseconds,thatdefinesa periodduringwhichLoop
Protecteventsarecounted.Thedefaultvalueis180seconds.Ifthetimerissetto0,the event
counterisnotresetuntiltheLoopProtecteventthresholdisreached.Ifthethreshold
isreached,
thatconstitutesaloopprotectionevent.
Example
ThisexampleshowshowtosettheLoopProtecteventwindowto120second s:
B2(rw)->set spantree lpwindow 120
show spantree lpwindow
UsethiscommandtodisplaythecurrentLoopProtecteventwindowvalue.
Syntax
show spantree lpwindow
value Specifiesthenumberofsecondsthatcomprisetheperiodduringwhich
LoopProtecteventsarecounted.Thedefaulteventwindowis180
seconds.