Vista de pagina 280
set spantree adminedge
SecureStack B2 Configuration Guide 9-39
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaytheedgeportstatusforfe.3.2:
B2(su)->show spantree adminedge port fe.3.2
Port
fe.3.2 has a Port Admin Edge of Edge-Port
set spantree adminedge
UsethiscommandtosettheedgeportadministrativestatusonaSpanningTreeport.
Syntax
set spantree adminedge port-string {true | false}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
Thedefaultbehavioroftheedgeportadministrativestatusbeginswiththevaluesettofalse
initiallyafterthedeviceispoweredup.IfaSpanningTreeBDPUisnotreceivedontheportwithin
afewseconds,thestatussettingchangestotrue.
Example
Thisexampleshowshowtosetfe.1.11asanedgeport:
B2(su)->set spantree adminedge fe.1.11 true
clear spantree adminedge
UsethiscommandtoresetaSpanningTreeporttononedgestatus.
Syntax
clear spantree adminedge port-string
portstring Specifiestheedgeport.Foradetaileddescriptionofpossibleportstring
values,refertoPortStringSyntaxUsedintheCLIonpage 72.
true|false Enables(true)ordisables(false)thespecifiedportasaSpanningTreeedge
port.